CHAPTER 5
NDA-24299
Page 102
Revision 1.0
DATA PROGRAMMING
Assignment of FCH Related Data
STEP 4:
AMND
Assign MND (Maximum Necessary Digits) including the access code
DC=752
MND=6
STEP 5:
ARNPL
Assign the access code to the logical route of speech path. It is not required to assign this data to the
logical route of signal controlling channel and dummy route.
LGRT=1
ACC=75
STEP 6:
ARNP
Enter “RT=0” for the self-office code (self-office identification code) in Open Numbering Network.
This number is used when Called Number Display for SMDR/Dterm/Desk Console, or CCIS
services, such as Call Back - CCIS/Message Reminder - CCIS/Message Waiting Lamp - CCIS, are
provided in this network.
RT=0
ACC=76
STEP 7:
AFRSL/AFRSN
Assign Number Pattern Code (NPC), including the access code for LCR, and the Outgoing Route
Selection Pattern (OPR) for the dummy route number.
LGRT=Dummy route numberNPC=75 OPR=75
STEP 8:
AOPRL/AOPRN
Assign the LCR routing pattern for the Outgoing Route Selection Pattern Routing (OPR) number.
The actual router selection pattern and the conditions are designated in this command.
TDPTN=0
OPR=1
LGRT=1SKIP=0