NDA-24299
CHAPTER 7
Page 163
Revision 1.0
TROUBLESHOOTING
3-C PM C-level Infinite Loop (Temporary)
3. 3-C PM C-level Infinite Loop (Temporary)
This message is displayed when the C-level program has been detected as abnormal by the Port
Microprocessor (PM) mounted on the FCH (PA-FCHA) card. In this instance, the system performs an
appropriate restart (B-monitor/Initial restart) according to the frequency of the failures. Refer to
. If the frequency exceeds 15 times an hour, it is judged as permanent. See
Figure 7-5 3-C PM C-level Infinite Loop (Temporary)
Note:
B-monitor Restart: Ports whose link has already been established remain connected, while ports processing
a call-origination may be released.
Initial Restart: All ports on the circuit card are force released to be placed in idle state.
3.1 Repair Procedure
STEP 1:
If the 3-C message has been displayed only once or twice, monitor the failure for a while. Otherwise,
move to STEP 2.
STEP 2:
Initialize the indicated FCH (PA-FCHA) card using the MB key. See
the FCH (PA-FCHA) card.”
When the LED on the FCH card lights green, and the related system messages are not displayed,
monitor the system for a while. Otherwise move to STEP 3.
STEP 3:
Replace the FCH card, following the procedure listed in
FCHA) card.”
4. 3-D PM Lockup Failure (Permanent)
The CPU sends diagnosis data at periodic intervals to the Port Microprocessor (PM) on FCH (PA-FCHA) cards
to monitor the PM. If the CPU cannot receive the return data within a predetermined time, the system displays
the data in
. When the failure is detected more than 15 times per hour, the failure is judged as
permanent. Otherwise, 3-E PM Lockup Failure (Temporary) is displayed.
Figure 7-6 3-D PM Lockup Failure (Permanent)
1. xx0x 0000 0000 0000 2. 0000 0000 0000 0000.........
MG
U
G
FCH Mounting Location
FCH Mounting Location
MG: Module Group (0/1)
U: Unit (0-3)
G: Group (00-23)
PM Restart Type
PM Restart Type
0/1 = B-monitor / Initial Restart
1. xx00 0000 0000 0000 2. 0000 0000 0000 0000.........
MG
U
G
FCH Mounting Location
FCH Mounting Location
MG: Module Group
U: Unit (0-3)
G: Group (00-23)
Содержание NEAX 2400 IPX
Страница 1: ...OCTOBER 2000 NEC America Inc NDA 24299 ISSUE 1 STOCK 200776 Fusion Network System Manual ...
Страница 15: ...LIST OF TABLES NDA 24299 Page x Revision 1 0 This page is for your notes ...
Страница 73: ...CHAPTER 4 NDA 24299 Page 58 Revision 1 0 This page is for your notes ...
Страница 159: ...CHAPTER 5 NDA 24299 Page 144 Revision 1 0 DATA PROGRAMMING Office Data Sheets This page is for your notes ...