APPENDIX D LIST OF CAUTIONS
User’s Manual U17446EJ3V1UD
396
(14/19)
Chapter
Cl
assi
fi
cati
on
Function Details
of
Function
Cautions Page
Hard
Vector table
address
No interrupt sources correspond to the vector table address 0014H.
p.223
pp.
IF0, IF1: Interrupt
request flag
registers 0, 1
MK0, MK1:
Interrupt mask
flag registers 0, 1
Because P30, P31, P41, and P43 have an alternate function as external
interrupt inputs, when the output level is changed by specifying the output
mode of the port function, an interrupt request flag is set. Therefore, the
interrupt mask flag should be set to 1 before using the output mode.
226, 227
Be sure to clear bits 0 and 1 to 0.
p.228
INTM0: External
interrupt mode
register 0
Before setting the INTM0 register, be sure to set the corresponding interrupt
mask flag (
××
MK
×
= 1) to disable interrupts. After setting the INTM0 register,
clear the interrupt request flag (
××
IF
×
= 0), then clear the interrupt mask flag
(
××
MK
×
= 0), which will enable interrupts.
p.228
Be sure to clear bits 2 to 7 to 0.
p.229
INTM1: External
interrupt mode
register 1
Before setting INTM1, set PMK3 to 1 to disable interrupts.
To enable interrupts, clear PIF3 to 0, then clear PMK3 to 0.
p.229
Interrupt request
pending
Interrupt requests will be held pending while the interrupt request flag registers
0, 1 (IF0, IF1) or interrupt mask flag registers 0, 1 (MK0, MK1) are being
accessed.
p.232
Chapter 1
3
Soft
Interrupt
function
Multiple interrupt
servicing
Multiple interrupts can be acknowledged even for low-priority interrupts.
p.233
Soft
−
The LSRSTOP setting is valid only when “Can be stopped by software” is set
for the low-speed internal oscillator by the option byte.
p.235
STOP mode
When shifting to the STOP mode, be sure to stop the peripheral hardware
operation before executing STOP instruction (except the peripheral hardware
that operates on the low-speed internal oscillation clock).
p.236
STOP mode,
HALT mode
The following sequence is recommended for operating current reduction of the
A/D converter when the standby function is used: First clear bit 7 (ADCS) and
bit 0 (ADCE) of the A/D converter mode register (ADM) to 0 to stop the A/D
conversion operation, and then execute the HALT or STOP instruction.
p.236
Hard
STOP mode
If the low-speed internal oscillator is operating before the STOP mode is set,
oscillation of the low-speed internal oscillation clock cannot be stopped in the
STOP mode (refer to Table 14-1).
p.236
Soft
To set and then release the STOP mode, set the oscillation stabilization time
as follows.
Expected oscillation stabilization time of resonator
≤
Oscillation stabilization
time set by OSTS
p.237
Hard
The wait time after the STOP mode is released does not include the time from
the release of the STOP mode to the start of clock oscillation (“a” in the figure
below), regardless of whether STOP mode was released by reset signal
generation or interrupt generation.
p.237
Chapter 1
4
Soft
Standby
function
OSTS:
Oscillation
stabilization time
select register
The oscillation stabilization time that elapses on power application or after
release of reset is selected by the option byte. For details, refer to CHAPTER
18 OPTION BYTE.
p.237