CHAPTER 11 SERIAL INTERFACE UART6
User’s Manual U17446EJ3V1UD
215
Minimum permissible data frame length: FLmin = 11
×
FL
−
×
FL = FL
Therefore, the maximum receivable baud rate at the transmission source is as follows.
BRmax = (FLmin/11)
−
1
= Brate
Similarly, the maximum permissible data frame length can be calculated as follows.
10
k + 2
21k
−
2
11
2
×
k
2
×
k
FLmax = FL
×
11
Therefore, the minimum receivable baud rate at the transmission source is as follows.
BRmin = (FLmax/11)
−
1
= Brate
The permissible baud rate error between UART6 and the transmission source can be calculated from the above
minimum and maximum baud rate expressions, as follows.
Table 11-5. Maximum/Minimum Permissible Baud Rate Error
Division Ratio (k)
Maximum Permissible Baud Rate Error
Minimum Permissible Baud Rate Error
8 +3.53%
−
3.61%
20 +4.26%
−
4.31%
50 +4.56%
−
4.58%
100 +4.66%
−
4.67%
255 +4.72%
−
4.73%
Remarks 1.
The permissible error of reception depends on the number of bits in one frame, input clock
frequency, and division ratio (k). The higher the input clock frequency and the higher the division
ratio (k), the higher the permissible error.
2.
k: Set value of BRGC6
22k
21k + 2
×
FLmax = 11
×
FL
−
×
FL = FL
21k – 2
20k
20k
21k
−
2
k
−
2
2k
21k + 2
2k
Содержание 78K0S/KB1+
Страница 2: ...User s Manual U17446EJ3V1UD 2 MEMO ...