CHAPTER 9 WATCHDOG TIMER
User’s Manual U17446EJ3V1UD
149
Table 9-2. Option Byte Setting and Watchdog Timer Operation Mode
Option Byte Setting
Low-Speed Internal Oscillator Cannot Be Stopped
Low-Speed Internal Oscillator Can Be Stopped
by Software
Watchdog timer clock
source
Fixed to f
RL
Note 1
.
•
Selectable by software (f
X
, f
RL
or stopped)
•
When reset is released: f
RL
Operation after reset
Operation starts with the maximum interval (2
18
/f
RL
).
Operation starts with the maximum interval
(2
18
/f
RL
).
Operation mode
selection
The interval can be changed only once.
The clock selection/interval can be changed only
once.
Features
The watchdog timer cannot be stopped.
The watchdog timer can be stopped
Note 2
.
Notes 1.
As long as power is being supplied, low-speed internal oscillator cannot be stopped (except in the reset
period).
2.
The conditions under which clock supply to the watchdog timer is stopped differ depending on the
clock source of the watchdog timer.
<1> If the clock source is f
X
, clock supply to the watchdog timer is stopped under the following
conditions.
•
When f
X
is stopped
•
In HALT/STOP mode
•
During oscillation stabilization time
<2> If the clock source is f
RL
, clock supply to the watchdog timer is stopped under the following
conditions.
•
If the CPU clock is f
X
and if f
RL
is stopped by software before execution of the STOP instruction
•
In HALT/STOP mode
Remarks 1.
f
RL
: Low-speed internal oscillation clock frequency
2.
f
X
: System clock oscillation frequency