APPENDIX D LIST OF CAUTIONS
User’s Manual U17446EJ3V1UD
398
(16/19)
Chapter
Cl
assi
fi
cati
on
Function Details
of
Function
Cautions Page
Chapter 1
7
Soft
Low-
voltage
detector
Cautions for low-
voltage detector
In a system where the supply voltage (V
DD
) fluctuates for a certain period in
the vicinity of the LVI detection voltage (V
LVI
), the operation is as follows
depending on how the low-voltage detector is used.
<1> When used as reset
The system may be repeatedly reset and released from the reset status.
In this case, the time from release of reset to the start of the operation of the
microcontroller can be arbitrarily set by taking action (1) below.
<2> When used as interrupt
Interrupt requests may be frequently generated. Take action (2) below.
p.263
Oscillation
stabilization time
on power
application or
after reset
release
The setting of this option is valid only when the crystal/ceramic oscillation clock
is selected as the system clock source. No wait time elapses if the high-speed
internal oscillation clock or external clock input is selected as the system clock
source.
p.267
Control of
RESET pin
Because the option byte is referenced after reset release, if a low level is input
to the RESET pin before the option byte is referenced, then the reset state is
not released.
Also, when setting 0 to RMCE, connect the pull-up resistor.
p.267
Selection of
system clock
source
Because the X1 and X2 pins are also used as the P121 and P122 pins, the
conditions under which the X1 and X2 pins can be used differ depending on
the selected system clock source.
(1) Crystal/ceramic oscillation clock is selected
The X1 and X2 pins cannot be used as I/O port pins because they are used
as clock input pins.
(2) External clock input is selected
Because the X1 pin is used as an external clock input pin, P121 cannot be
used as an I/O port pin.
(3) High-speed internal oscillation clock is selected
P121 and P122 can be used as I/O port pins.
p.267
If it is selected that low-speed internal oscillator cannot be stopped, the count
clock to the watchdog timer (WDT) is fixed to low-speed internal oscillation
clock.
p.268
Low-speed
internal oscillates
If it is selected that low-speed internal oscillator can be stopped by software,
supply of the count clock to WDT is stopped in the HALT/STOP mode,
regardless of the setting of bit 0 (LSRSTOP) of the low-speed internal
oscillation mode register (LSRCM). Similarly, clock supply is also stopped
when a clock other than the low-speed internal oscillation clock is selected as
a count clock to WDT.
While the low-speed internal oscillator is operating (LSRSTOP = 0), the clock
can be supplied to the 8-bit timer H1 even in the STOP mode.
p.268
Chapter 1
8
Hard
Option byte
Use of RESET
pin as an input-
only port pin
(P34)
Be aware of the following when re-erasing/-writing (by on-board programming
using a dedicated flash memory programmer) an already-written device which
has been set as “The RESET pin is used as an input-only port pin (P34)” by
the option byte function.
Before supplying power to the target system, connect a dedicated flash
memory programmer and turn its power on. If the power is supplied to the
target system beforehand, the flash memory programming mode cannot be
switched to.
p.268