CHAPTER 6 16-BIT TIMER/EVENT COUNTER 00
Preliminary User’s Manual U16846EJ1V0UD
141
(8) Timer
operation
<1> Even if 16-bit timer counter 00 (TM00) is read, the value is not captured by 16-bit timer capture/compare
register 010 (CR010).
<2> Regardless of the CPU’s operation mode, when the timer stops, the input signals to the TI000/TI010 pins
are not acknowledged.
<3> The one-shot pulse output mode operates correctly only in the free-running mode and the mode in which
clear & start occurs at the TI000 valid edge. In the mode in which clear & start occurs on a match between
the TM00 register and CR000 register, one-shot pulse output is not possible because an overflow does not
occur.
(9) Capture
operation
<1> If the TI000 pin valid edge is specified as the count clock, a capture operation by the capture register
specified as the trigger for TI000 is not possible.
<2> To ensure the reliability of the capture operation, the capture trigger requires a pulse two cycles longer than
the count clock selected by prescaler mode register 00 (PRM00).
<3> The capture operation is performed at the falling edge of the count clock. An interrupt request input
(INTTM000/INTTM010), however, is generated at the rise of the next count clock.
(10) Compare operation
A capture operation may not be performed for CR000/CR010 set in compare mode even if a capture trigger has
been input.
(11) Edge detection
<1> If the TI000 or TI010 pin is high level immediately after system reset and the rising edge or both the rising
and falling edges are specified as the valid edge of the TI000 or TI010 pin to enable the 16-bit timer counter
00 (TM00) operation, a rising edge is detected immediately after the operation is enabled. Be careful
therefore when pulling up the TI000 or TI010 pin. However, the rising edge is not detected at restart after
the operation has been stopped once.
<2> The sampling clock used to eliminate noise differs when the TI000 pin valid edge is used as the count clock
and when it is used as a capture trigger. In the former case, the count clock is f
X
, and in the latter case the
count clock is selected by prescaler mode register 00 (PRM00). The capture operation is started only after
a valid level is detected twice by sampling the valid edge, thus eliminating noise with a short pulse width.