Technical Manual N5 (CANopen)
6 Operating modes
The following applies here: cycle time = value of 60C2
:01
h
* 10
value of 60C2:02
seconds.
•
:02
h
(Interpolation Time Index): This object specifies the time basis of the cycles. Currently,
h
:02
h
=-3 is supported; this yields a time basis of 1 millisecond.
The following objects can be read in this mode:
•
h
(Position Actual Value)
•
(Velocity Actual Value)
•
(Following Error Actual Value)
6.8 Cyclic Synchronous Velocity
6.8.1 Overview
Description
In this mode, the controller passes a speed preset via the fieldbus at fixed time intervals (referred to in
the following as a cycle). The controller then no longer calculates any ramps, but rather only follows the
presets.
Note
The limit switches and, thus, the tolerance bands are active in this mode. For further information on
the limit switches, see Limitation of the range of motion.
Activation
To activate the mode, the value "9" must be set in object 6060
h
(Modes Of Operation) (see "CiA 402
Controlword
In this mode, the bits of controlword 6040
have no special function.
Statusword
The following bits in object 6041
(statusword) have a special function:
Bit
Value
Description
8
0
The controller is not in sync with the fieldbus
8
1
The controller is in sync with the fieldbus
10
0
Reserved
10
1
Reserved
12
0
Controller does not follow the target; the preset of 60FF
h
(Target Velocity) is
ignored
12
1
Controller follows the target; object 60FF
(Target Velocity) is used as the
input for position control.
13
0
Reserved
13
1
Reserved
6.8.2 Object entries
The following objects are necessary for controlling this mode:
•
(Target Velocity): This object must be written cyclically with the speed set value.
Version: 2.0.1 / FIR-v1650