Technical Manual N5 (CANopen)
5 General concepts
Commissioning
An auto setup must be performed before using closed loop mode. The auto setup operating mode
automatically determines the necessary parameters (e.g., motor data, feedback systems) that are
necessary for optimum operation of the field oriented control. All information necessary for performing
the auto setup can be found in chapter Auto setup.
To use closed loop mode, certain settings are necessary depending on the motor type and feedback;
see chapter Setting the motor data. Bit 0 in 3202
must be set . If the encoder is used for the
commutation, the index of the encoder must be passed over at least once after switching on (bit 15 in
6041h Statusword is set).
5.2 CiA 402 Power State Machine
5.2.1 State machine
CiA 402
To switch the controller to the ready state, it is necessary to run through a state machine. This is
defined in CANopen standard 402. State changes are requested in object 6040
h
(controlword). The
actual state of the state machine can be found in object 6041
(statusword).
Controlword
State changes are requested via object 6040
h
(controlword).
State transitions
The diagram shows the possible state transitions.