![NANOTEC ELECTRONIC N5 Скачать руководство пользователя страница 307](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153307.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
0001
h
Firmware version
FIR-v1426
Change history
Description
Value
Description
-32768 … -1
Reserved
0
Immediate stop
1
Braking with "slow down ramp" (deceleration (deceleration ramp) depending
on operating mode) and subsequent state change to "Switch on disabled"
2 … 32767
Reserved
605Dh Halt Option Code
Function
The object contains the action that is to be executed if bit 8 (Halt) is set in controlword 6040
.
Object description
Index
605D
h
Object name
Halt Option Code
Object Code
VARIABLE
Data type
INTEGER16
Savable
yes, category: application
Access
read / write
PDO mapping
no
Allowed values
Preset value
0001
h
Firmware version
FIR-v1426
Change history
Description
Value
Description
-32768 … 0
Reserved
1
Braking with "slow down ramp" (deceleration (deceleration ramp) depending
on operating mode)
2
Braking with "quick stop ramp" (deceleration (deceleration ramp) depending
on operating mode)
3 … 32767
Reserved
Version: 2.0.1 / FIR-v1650