![NANOTEC ELECTRONIC N5 Скачать руководство пользователя страница 329](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153329.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
02
h
Subindex
01
h
Name
Speed During Search For Switch
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000032
h
Subindex
02
h
Name
Speed During Search For Zero
Data type
UNSIGNED32
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
0000000A
h
Description
This value is calculated with the numerator in object 2061
and the dominator in object 2062
h
.
The speed for the search for the switch is specified in subindex 1.
The (lower) speed for the search for the reference position is specified in subindex 2.
Note
•
The speed in subindex 2 is simultaneously the initial speed when starting the acceleration ramp.
If this is set too high, the motor loses steps or fails to turn at all. If the setting is too high, the
index marking will be overlooked. The speed in subindex 2 should therefore be less than 1000
steps per second.
•
The speed in subindex 1 must be greater than the speed in subindex 2.
609Ah Homing Acceleration
Function
Specifies the acceleration ramp for Homing Mode in user-defined units.
Version: 2.0.1 / FIR-v1650
329