10 Description of the object dictionary
Program 2: subindex 3 and 4
Program 3: subindex 5 and 6
Program 4: subindex 7 and 8
Example: Program 1 with designation "
test.usr
" is, thus, coded as follows:
t = 74
h
e = 65
h
s = 73
h
This yields the two entries in subindices 1 and 2:
74657374
h
,
00000000
h
Coded in each of two successive subindices in the ASCII character set is the name of a user program.
The subindex with the UB (upper byte) designation contains the first four letters of the name, the
subindex with the LB (lower byte) designation contains the last four letters. If the name has less than
eight letters, the missing letters must be filled with zeros.
230Fh Uptime Seconds
Function
This object contains the operating hours in seconds since the last time the controller was started.
Note
This object is not stored; counting begins with "0" again after switching on.
Object description
Index
230F
h
Object name
Uptime Seconds
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
no
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1436
Change history
2310h NanoJ Input Data Selection
Function
Describes the object dictionary entries that are copied to the PDO mapping input of the NanoJ
program.
Version: 2.0.1 / FIR-v1650
255