Technical Manual N5 (CANopen)
10 Description of the object dictionary
PDO mapping
no
Allowed values
Preset value
03
h
Subindex
01
h
Name
Enable Legacy Power Mode
Data type
INTEGER8
Access
read / write
PDO mapping
no
Allowed values
Preset value
00
h
Subindex
02
h
Name
Override Field Inversion
Data type
INTEGER8
Access
read / write
PDO mapping
no
Allowed values
Preset value
00
h
Subindex
03
h
Name
Do Not Touch Controller Settings
Data type
INTEGER8
Access
read / write
PDO mapping
no
Allowed values
Preset value
00
h
Description
Valid values for subindex 01
h
:
•
Value = "0": In the "Switched on" state of the CiA 402 Power State Machine, the output voltage for
the motor (PWM) is permanently set to 50%; no holding torque is built up.
•
Value = "1": In the "Switched on" state of the CiA 402 Power State Machine, the output voltage
for the motor (PWM) is active via the controller; holding torque is built up. The motor remains at a
standstill.
Valid values for subindex 02
h
:
•
Value = "0": Use default values of the firmware
•
Value = "1": Force non-inversion of the rotating field (mathematically positive)
•
Value = "-1": Force inversion of the rotating field (mathematically negative)
Valid values for subindex 03
h
:
•
Value = "0": Auto setup detects the motor type (stepper motor or BLDC motor) and uses the
corresponding pre-configured parameter set.
•
Value = "1": Perform auto setup with the values for the controller that were entered in object 3210
h
before the auto setup; the values in 3210
are not changed.
Version: 2.0.1 / FIR-v1650