![NANOTEC ELECTRONIC N5 Скачать руководство пользователя страница 269](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153269.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Subindex
02
h
Name
Torque
Data type
INTEGER32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Subindex
03
h
Name
Velocity
Data type
INTEGER32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000001
h
Subindex
04
h
Name
Position
Data type
INTEGER32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000001
h
Description
The following subindices have a function:
•
01
h
: Not used
•
02
h
: Not used
•
03
h
: Changes the source of object 6044
:
•
Value = "-1": The internally calculated set value is entered in object 6044
h
•
Value = "0": The value is kept at 0
•
Value = "1": The encoder value is entered in object 6044
•
04
h
: Changes the source of object 6064
:
•
Value = "-1": The internally calculated set value is entered in object 6064
h
•
Value = "0": The value is kept at 0
•
Value = "1": The encoder value is entered in object 6064
3210h Motor Drive Parameter Set
Function
Contains the P and I components of the current, distance and position controllers for open loop (only
current controller activated) and closed loop.
Version: 2.0.1 / FIR-v1650
269