![NANOTEC ELECTRONIC N5 Скачать руководство пользователя страница 323](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153323.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Object description
Index
6083
h
Object name
Profile Acceleration
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
000001F4
h
Firmware version
FIR-v1426
Change history
6084h Profile Deceleration
Function
Specifies the maximum deceleration (deceleration ramp) in user-defined units.
Object description
Index
6084
h
Object name
Profile Deceleration
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
000001F4
h
Firmware version
FIR-v1426
Change history
6085h Quick Stop Deceleration
Function
Specifies the maximum Quick Stop Deceleration in user-defined units.
Object description
Index
6085
h
Object name
Quick Stop Deceleration
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
Version: 2.0.1 / FIR-v1650
323