Technical Manual N5 (CANopen)
4 Commissioning
Example
Accessing a value in the object dictionary:
http://192.168.2.100/od/6040/00
This string is used to access entry 6040
subindex 0 in the object dictionary.
The reply is made as a JSON string and reflects the content of this object.
Accessing the file system
The following URIs enable access to the file system:
<IP address>/fs
Lists the root directory.
<IP address>/fs/dir
Lists the subdirectory.
<IP address>/fs/dir/file.xxx
Requests file "file.xxx" from directory "dir".
Files are uploaded with the
PUT
command,
GET
is used to download and
DELETE
is used to delete.
Note
Deleting files may place the controller in a non-functional state.
Accessing the object dictionary
The following URIs enable access to the object dictionary:
<IP address>/od/xxxx/yy
Requests entry xxxx subindex yy from the object dictionary.
<IP address>/od/xxxx/Data
Requests entry xxxx with all subindices.
4.1.4 NanoIP
General
The controller is equipped with an integrated web server (NanoIP) that can be queried with a web
browser. With NanoIP, the controller can be configured and parameterized, including access to the
internal file system for loading sequence programs (NanoJ programs).
Note
There are no guaranteed execution and response times when accessing the web server of the
controller.
In extreme cases, these may vary by several seconds. Access via a web server is therefore not
suited for directly controlling the motor and should only be used for commissioning/diagnosis or
troubleshooting.