![NANOTEC ELECTRONIC N5 Скачать руководство пользователя страница 217](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153217.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Access
read only
PDO mapping
no
Allowed values
Preset value
Firmware version
FIR-v1540
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
01
h
Subindex
01
h
Name
BL Config
Data type
UNSIGNED32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Description
The subindices have the following functions:
•
Subindex 01: If the value "1" is written in the object, the boot loader suppresses the boot-up
message and only the firmware sends a BOOTUP message. With a "0", the boot loader and the
firmware each send a BOOTUP message.
2009h CANopen NodeID
Function
This object contains the node-ID of the controller. See chapter Commissioning.
Object description
Index
2009
h
Object name
CANopen NodeID
Object Code
VARIABLE
Data type
UNSIGNED8
Savable
yes, category: communication
Access
read / write
PDO mapping
no
Version: 2.0.1 / FIR-v1650
217