7.2Troubleshooting
7-19
7.2.3
Trouble shooting example for input signal inconsistency failure
When an inconsistency is detected in the redundunt type signals that are inputted to the RMU,
"E1105" will be detected.
When this happens, please check the error code and assis code to ideitify the signal in which the error is
detected.
[Error assist code]
Assist code
SUB1
Assist code
SUB2
Assist code
SUB3
Description
1
Safety input 1
"Robot emergency stop signal" is inconsistent.
2
Safety input 2
"Enable switch signal" is inconsistent.
4
Safety input 3
"Slave error signal" is inconsistent.
8
Safety input 4
"Robot LS detection signal" is inconsistent.
16
Safety input 5
"Emergency stop signal" is inconsistent.
32
Safety input 6
"Safety plug signal" is inconsistent.
64
Safety input 7
"Protective stop signal" is inconsistent.
16
128
Safety input 8
"External enable signal" is inconsistent.
1
Safety input 9
"General input 1 signal" is inconsistent.
2
Safety input 10
"General input 2 signal" is inconsistent.
4
Safety input 11
"General input 3 signal" is inconsistent.
8
Safety input 12
"General input 4 signal" is inconsistent.
48
16
Safety input 13
"General input 5 signal" is inconsistent.
(NOTE) When plural errors happen at the same time in ASSIST CODE SUB1, the ASSIST CODE SUB 2 value will become
the total number of each value.
This is an example in which "Robot emergency stop input signal inconsistency" occurs.
Signal name
Assist code
SUB1:SUB2
Description
Robot
emergency
stop
16:1
Inconsistency of emergency stop button inputs of the operation
panel or the teach pendant
E1105 ( #1: 16: 1: 0)
Robot number
(In this example, error occured in
robot 1)
Assist code SUB1
Assist code SUB2
Assist code SUB3
Содержание RMU20-20
Страница 2: ......
Страница 6: ...Contents 4 ...
Страница 8: ......
Страница 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Страница 68: ...2 9 Enabling RMU 2 40 NOTE ...
Страница 70: ......
Страница 86: ...3 2Operation procedure 3 16 Top Display Form Limit Side Display Sphere Limit Side Display Form Limit ...
Страница 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Страница 102: ......
Страница 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Страница 144: ......
Страница 154: ...5 4Trouble shooting 5 10 NOTE ...
Страница 156: ......
Страница 166: ...6 4Trouble shooting 6 10 NOTE ...
Страница 168: ......
Страница 189: ......