7.2Troubleshooting
7-12
Assist code
Error
Error code
Top: Controller
Bottom: RMU
1
2
3
Description of trouble
Remedy
16-23
Pole
position
differen
ce
- -
32-39
Pole
wiring
disconn
ection
- -
48-55
Only
pole
has
moved
- -
Position
monitoring error
E1110
E09
64-71
Detecti
on
circuit
failure
- -
This error occurs if a failure
happen in the monitoring of
the pole position.
Check the motor and
encoder connections.
Check the pole position
signal cable between the
drive unit and the RMU.
Assist code
SUB1
Assist code
SUB2
Description
16-23
-
If there is a big difference between the encoder position and the pole
position when the motor is moving, this error occurs.
16: 1st axsi, 23: 8th axis
32-39
-
If the wiring for the motor pole position detection is disconnected, this error
occurs.
32: 1st axis, 39:8th axis
48-55
-
If only the motor pole position moves and the encoder position does not
move, this error occurs.
48:1st axis, 55:8th axis
64-71
-
If a failure happen in the pole position detection circuit, this error occurs.
64:1st axis, 71:8th axis
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB1
SUB 2
SUB 3
Description of trouble
Remedy
Position
monitoring
disparity error
E1111
E10
- - -
This error occurs if there is
too great difference between
the two position values
calculated by each CPU.
The difference is normally
cleared when the robot
stops, and Motors ON can
be initiated again.
If the trouble persists, the
RMU may be broken.
Assist code
Error
Error code
Top: Controller
Bottom: RMU
SUB 1
SUB 2
SUB 3
Description of trouble
Remedy
Speed
monitoring
disparity error
E1112
E11
- - -
This error occurs if there is
too great difference between
the two speed values
calculated by each CPU.
The difference is normally
cleared when the robot
stops, and Motors ON can
be initiated again.
If the trouble persists, the
RMU may be broken.
Содержание RMU20-20
Страница 2: ......
Страница 6: ...Contents 4 ...
Страница 8: ......
Страница 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Страница 68: ...2 9 Enabling RMU 2 40 NOTE ...
Страница 70: ......
Страница 86: ...3 2Operation procedure 3 16 Top Display Form Limit Side Display Sphere Limit Side Display Form Limit ...
Страница 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Страница 102: ......
Страница 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Страница 144: ......
Страница 154: ...5 4Trouble shooting 5 10 NOTE ...
Страница 156: ......
Страница 166: ...6 4Trouble shooting 6 10 NOTE ...
Страница 168: ......
Страница 189: ......