7.2Troubleshooting
7-10
Assist code
Error
Error code
Top: Controller
Bottom: RMU
1
2
3
Description of trouble
Remedy
16
1 Safety input 1
2 Safety input 2
4 Safety input 3
8 Safety input 4
16 Safety input 5
32 Safety input 6
64 Safety input 7
128 Safety input 8
Disparity error
of input signal
E1105
E07
48
1 Safety input 9
2 Safety input 10
4 Safety input 11
8 Safety input 12
16 Safety input 13
-
This error occurs when
the redundant safety
signals which are input
to the RMU have been
detected as different
logic.
If a robot emergency
stop disparity has been
detected, the
emergency stop output
is turned OFF. When
any other disparity has
been detected, the
power supply output is
turned OFF.
After removing the cause
of the error, turn OFF both
of those redundunt
signals, and then press
[Reset] key twice.
Please refer to “2.3.2
safety inputs” table 2-10
for the detail of safety
input signals.
Assist code
SUB1
Assist code
SUB2
Assist code
SUB3
Description
1
Safety input 1
"Robot emergency stop signal" is inconsistent.
2
Safety input 2
"Enable switch signal" is inconsistent.
4
Safety input 3
"Slave error signal" is inconsistent.
8
Safety input 4
"Robot LS detection signal" is inconsistent.
16
Safety input 5
"Emergency stop signal" is inconsistent.
32
Safety input 6
"Safety plug signal" is inconsistent.
64
Safety input 7
"Protective stop signal" is inconsistent.
16
128
Safety input 8
"External enable signal" is inconsistent.
1
Safety input 9
"General input 1 signal" is inconsistent.
2
Safety input 10
"General input 2 signal" is inconsistent.
4
Safety input 11
"General input 3 signal" is inconsistent.
8
Safety input 12
"General input 4 signal" is inconsistent.
32
16
Safety input 13
"General input 5 signal" is inconsistent.
(NOTE) When plural errors happen at the same time in ASSIST CODE SUB1, the ASSIST CODE SUB 2 value will become
the total number of each value.
Содержание RMU20-20
Страница 2: ......
Страница 6: ...Contents 4 ...
Страница 8: ......
Страница 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Страница 68: ...2 9 Enabling RMU 2 40 NOTE ...
Страница 70: ......
Страница 86: ...3 2Operation procedure 3 16 Top Display Form Limit Side Display Sphere Limit Side Display Form Limit ...
Страница 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Страница 102: ......
Страница 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Страница 144: ......
Страница 154: ...5 4Trouble shooting 5 10 NOTE ...
Страница 156: ......
Страница 166: ...6 4Trouble shooting 6 10 NOTE ...
Страница 168: ......
Страница 189: ......