1.1 Outline
1-15
Precautions related to the connection to the terminal block TBX-1
Applicable connection tool: Minus screw driver (Width of the edge is 2.6mm)
Wire size
Regarding the size of the wires for the external I/O device connection, refer to the following descriptions.
Single wire:
φ
1.6 mm, Twisted wire(Flexible wire):
φ
1.25mm
2
When connecting the wire as it is, the pealed length of the wire should be 11mm.
Concerning the connection, it is strongly recommended to use blade-shape terminal with a plastic insulator for
the wire to prevent the electric short-circuit with the peripheral devices. In a case like that, please select a
terminal whose connection portion length is 11 mm or more.