4.1Configuration flow of setting procedure
4-2
<1> In case that the RMU has been replaced or the data was initialized
When the RMU is replaced, or backup-restore is executed, perform the settings in the following sequence.
When the power is turned on, "E1107 Robot monitoring unit is not approved" will occur. But this is normal.
In that case, perform the following steps.
1
Setting of parameters
Set the parameter for the RMU.
2
Confirmation of parameters
Confirm the parameters which have been set.
DANGER
Please make sure the parameter values are changed correctly
in the confirmation screen of the parameter. If the parameter is
not set correctly, the robot does not work in the intended
function will be death or serious injury accidents.
3
Approval (*)
Confirm that the monitoring unit parameters and robot controller parameters
are the same. Robot can not be operated without approval.
Power OFF and ON
4
Turn OFF and ON the power of the robot controller.
(*) At first visually check that these parameters are the same between the RMU and the controller by referring
to "4.3Confirmation of parameters". Next perform “Approval” procedure (This means that the setting is correct).
If this approval procedure is not finished, robot can not be operated.
Содержание RMU20-20
Страница 2: ......
Страница 6: ...Contents 4 ...
Страница 8: ......
Страница 26: ...1 4 EC DECLARATION OF CONFORMITY FOR MACHINERY 1 18 NOTE ...
Страница 68: ...2 9 Enabling RMU 2 40 NOTE ...
Страница 70: ......
Страница 86: ...3 2Operation procedure 3 16 Top Display Form Limit Side Display Sphere Limit Side Display Form Limit ...
Страница 100: ...3 4 Setting when a slider unit is used 3 30 NOTE ...
Страница 102: ......
Страница 138: ...4 4Approval 4 36 8 Approval is completed The following screen will be displayed ...
Страница 144: ......
Страница 154: ...5 4Trouble shooting 5 10 NOTE ...
Страница 156: ......
Страница 166: ...6 4Trouble shooting 6 10 NOTE ...
Страница 168: ......
Страница 189: ......