Page 68 MSI-3750CS RF Weighmeter • User Guide
3750CS
C
ELL
S
CALE RF DIGITAL WEIGHT INDICATOR
®
Length: 5 Justification: left, leading hours zero suppressed
@T4
1 4 : 0 8 : 3 6
Length: 8 Justification: left, leading hours zero suppressed
@U
PRINT CURRENT UNITS
Use the @U command to output the current weight units.
Input Data Form: @U
Output Data Form:
@U
L B K G O Z G
Length: 4 Justification: left
(Units available depend on capacity and legal-for-trade setups)
@V
PRINT WEIGHT (No Mode or Units)
Use the @V command to print the current weight without units or mode printed.
@V is not available on LFT configured 3750s
Input Data Form:
@V1
Displayed weight (GROSS, NET, DEV, %DEV)
@V2
Gross weight
@V3
Net weight
Note: will print dashes if NET mode is not enabled
@V4
Tare weight
Note: will print zeros if no TARE value has been established
@V5
Total weight
@V6
n Totals (weighments counter)
@V7
Total + n Totals (Combined @V5 and @V6)
@V8
Lower Display
Note: prints the lower display as setup by the user.
@V9
Last Totaled Weight
Note: will print dashes if no weight has been totaled.
Output Data Form:
@V1 @V2 @V3 @V4 @V9
2 0 . 5 0 2
Length: 8 Justification: full, leading hours zero suppressed
@V5
1 2 3 4 5 6 7 . 8 9
Length: 10 Justification: right, leading zeros suppressed
@V6
1 2 3 4
Length: 5 Justification: right, leading zeros suppressed
@V7
1 2 3 4 5 6 7 . 8 9 , 1 2 3 4
Length: 16 Justification: each number field - right, leading zeros suppressed
@V8
* * * * * * * *
Length: 8 or 9 if DP is present
@W
PRINT WEIGHT FULLY
Use the @W command to print the current weight with units and mode printed.
Input Data Form:
@W1
Displayed weight with units and mode
@W2
Gross weight
@W3
Net weight
Note: will print dashes if NET mode is not enabled
@W4
Tare weight
Note: will print zeros if no Tare value has been established
@W5
Total weight
@W6
n Totals (weighments counter)
@W7
Total with n Totals (combined @W5 and @W6)
@W8