Page 18 MSI-3750CS RF Weighmeter • User Guide
3750CS
C
ELL
S
CALE RF DIGITAL WEIGHT INDICATOR
®
To Use Tare Up/Down
(TARE key function must be set to “KBD/UPDN”)
To Read the Tare Value
(without changing it) TARE key function must be set to “KBD/UPDN”.
1
1
2
CLEARING
1) Push TARE. The message display reads “TARE”
and the current Tare value appears on the numeric
digits for 2 seconds. Note or Print the value as
desired.
1) Push TARE followed by ` CLR (ZERO). The mes-
sage display reads “CLEARING”. The scale returns
to the GROSS mode.
Alternate method: Remove all weight from the scale (Gross Zero) and push
TARE. The message display temporarily reads “TARING”. Then the scale
returns to the GROSS mode.
To Clear Tare and Revert to Net Mode
To Keyboard Tare
(TARE key function must be set to “KBD/UPDN”)
1
2
3
4
1
2
2
3
1) Push TARE. The display reads “TARE”. Any current
Tare value is displayed.
You have only three seconds to start step 2.
2) Using the numeric keys input the value desired. In
this example we’ll use 0.5 lb. as a Tare Value.
The 3750CS will automatically place a leading zero if the Tare value starts
with the decimal point.
3) The Tare Value “0.5” is displayed.
4) Push ENTER to place the value in the Tare Register.
The display reads “TARE SET” and displays the
Tare value for 1 second. All subsequent readings
have the Tare value subtracted and are displayed
in “NET” weight.
1) Push TARE. The display reads “TARE”. Any current
Tare value is displayed. In this example a value of
9.5 lb. was previously Tared.
2) Within 2 seconds after pushing the TARE key,
use the UP or DOWN scroll keys to increment or
decrement the Tare value. Each single push of the
scroll keys will change the current Tare value 1
scale division. In this example, the scale increment
is .5 lb.
3) The Tare Value “10.5” is displayed. Push ENTER
to place the value in the Tare Register. The display
reads “TARING” followed by “TARE SET” and
displays the Tare value for 1 second. All subsequent
readings have the Tare value subtracted and are
displayed in “NET” weight.