Page 26 MSI-3750CS RF Weighmeter • User Guide
3750CS
C
ELL
S
CALE RF DIGITAL WEIGHT INDICATOR
®
SECTION 5 – ID CODES
• The CellScale can store 32 ID codes. The 3750CS controls which ID Code is in use.
• Each ID Code stores a Tare Value, a Total Value, a weighment counter, display mode (Net, Gross, Peak, etc..),
Unit (lb., kg, ton, etc.), and two 20 byte ID code strings. Each ID code also computes and stores statistics of
Average, Min., Max., Standard Deviation, and Coefficient of Variance.
• ID Codes are created when a new name is entered by the user. The name can be all numbers, all letters, or a
combination of numerals and letters. Once the name is entered by the user, the CellScale scans its memory
to see if the ID Code already exists. If it does, all new totaled weighments are added to the previously totaled
weighments, and any preexisting Tare value will be used for NET weight computation. If the name did not
already exist, the CellScale creates a new ID Code.
• ID Codes are alphabetized when created using the standard ASCII convention.
• The 3750CS provides a way to scroll through all existing ID Codes as an alternate means of selecting
an existing ID code.
ID CODE ORGANIZATION