1-56
Computer Group Literature Center Web Site
Board Description and Memory Maps
1
SCSI Parity Error
Note
The 400/500-Series MVME172 models do not contain parity
DRAM.
Description:
Parity error detected while the 53C710 was reading DRAM.
MPU Notification:
53C710 Interrupt.
Status:
53C710 DMA Status Register 53C710 DMA Interrupt Status Register
MC2 chip SCSI Error Status Register ($FFF4202C).
Comments:
53C710 interrupt enables are controlled in the 53C710 and in the MC2
chip SCSI Interrupt Control Register ($FFF4202F).
SCSI Off-Board Error
Description:
Error encountered while the 53C710 was attempting to go to the VMEbus.
MPU Notification:
53C710 Interrupt.
Status:
53C710 DMA Status Register 53C710 DMA Interrupt Status Register
MC2 chip SCSI Error Status Register ($FFF4202C).
Comments:
53C710 interrupt enables are controlled in the 53C710 and in the MC2
chip SCSI Interrupt Control Register ($FFF4202F).
SCSI LTO Error
Description:
Local Bus Time-out occurred while the 53C710 was local bus master.
Содержание MVME172
Страница 1: ...MVME172 VME Embedded Controller Programmer s Reference Guide VME172A PG2 Edition of February 1999 ...
Страница 6: ...Place holder ...
Страница 18: ...xviii ...
Страница 78: ...1 60 Computer Group Literature Center Web Site Board Description and Memory Maps 1 ...
Страница 332: ...5 42 Computer Group Literature Center Web Site MCECC 5 ...
Страница 336: ...A 4 Related Documentation A ...
Страница 340: ...VMEchip2 Tick Timer 1 Periodic Interrupt Example B 4 Computer Group Literature Center Web Site B ...
Страница 352: ...Index IN 12 Computer Group Literature Center Web Site I N D E X ...
Страница 354: ......