MC40 Integrator Guide
♦
2 Check Digits
- Bar code contains two check digits.
–
Report Check Digit
- Transmit Code 11 data with or without the check digit. A check in the checkbox
indicates to send Code 11 data with check digit (default - disabled).
•
Matrix 2 of 5
–
Length1
- Use to set decode lengths (default - 10). See
for more information.
–
Length2
- Use to set decode lengths (default - 0). See
for more information.
–
Redundancy
- Sets the reader to read the bar code twice before accepting data. A check in the checkbox
indicates that redundancy is enabled (default - disabled).
–
Report Check Digit
- Transmit Matrix 2 of 5 data with or without the check digit. A check in the checkbox
indicates to send Matrix 2 of 5 data with check digit (default - enabled).
–
Verify Check Digit
- Enable this feature to check the integrity of all Matrix 2 of 5 symbols to verify that the
data complies with a specified check digit algorithm (default - enabled).
•
UPCE1
–
Report Check Digit
- The check digit is the last character of the symbol used to verify the integrity of the
data. Enables or disables this option. A check in the checkbox indicates that the option is enabled (default
- disabled).
–
Preamble
- Preamble characters are part of the UPC symbol consisting of Country Code and System
Character. Select the appropriate option to match the host system.
There are three options for transmitting a UPCE1 preamble:
♦
Preamble Sys Char
- Transmit System Character only.
♦
Preamble Country and Sys Char
- Transmit System Character and Country Code (“0” for USA).
♦
Preamble None
- Transmit no preamble (default).
–
Convert UPCE1 To UPCA
- Enable this to convert UPCE1 decoded data to UPC-A format before
transmission. After conversion, the data follows UPC-A format and is affected by UPC-A programming
selections. Disable this to transmit UPCE1 decoded data as UPCE1 data, without conversion (default
- disabled).
Decode Lengths
The allowable decode lengths are specified by options
Length1
and
Length2
as follows:
• Variable length: Decode symbols containing any number of characters.
– Set both
Length1
and
Length2
to 0.
• Range: Decode a symbol with a specific length range (from
a
to
b
, including
a
and
b
).
– Set
Length1
to
a
and set
Length2
to
b
.
• Two Discrete Lengths: Decode only symbols containing either of two selected lengths.
– Set both
Length1
or
Length2
to the specific lengths.
Length1
must be greater than
Length2
.
• One Discrete Length: Decode only symbols containing a specific length.
– Set both
Length1
and
Length2
to the specific length.
4-14
MN000112A01 - September 2013