A-58 OPERATION PANELS
6
DATA INPUT/OUTPUT
By using an external I/O device, data can be written to the NC memory and data in the NC
memory can be output. The I/O destination (I/O channel) must be specified in advance.
6-1
Setting the I/O destination (I/O channel)
1)
Connect the external I/O device.
2)
Display the Setting screen.
Function selection key
(OFS/SET)
[SETTING]
3)
Enter the channel number of the connected external I/O device at "I/O CHANNEL".
If using a memory card, set "4".
4)
Press the INPUT key.
Once set, the parameter settings do not need to be changed unless the external I/O device is
changed.
6-2
Inputting/Outputting a Program
1.
Make sure that the I/O device has been set.
2.
If a program is input without designating a program number, the NC data must begin
with a program number preceded by "O" or ":". An input error occurs if a program
number is not designated.
3.
NC data that doesn't contain an O number may be input by designating a program
number.
4.
If the data to be input has multiple EOB codes followed by O numbers, the programs
are registered under the individual O numbers.
6-2-1
Program Input Operating Procedure
<Input from a memory card>
1)
Insert a memory card into the card slot.
2)
Set the PANEL key-switch to the
(PANEL/EDIT) position.
3)
Select the mode selection switch
(EDIT).
The edit mode will be selected.
4)
Display the PROGRAM EDIT screen or PROGRAM DIRECTORY screen.
Function selection key
(PROG)
5)
Press the
[(OPRT)]
→
[+]
→
[READ]
soft-keys.
NOTE
PROG