OPERATION PANELS A-33
5-7
Status Indicators
The status indicators are used to confirm the status of the machine.
The individual status indicators light or blink in the
following cases:
1.
When the machine is at the reference position for an
intended operation.
2.
When the machine has stopped during an automatic
operation.
3.
When an alarm has occurred.
Status Indicator
Contents of Indication
The status indicator
[ERR]
is lit or blinks if an alarm state is detected.
The status indicator
[ERR]
is lit when a program error occurs.
The status indicator
[ERR]
blinks when a machine error occurs.
If an alarm occurs, the corresponding alarm message is displayed on
the screen.
The status indicator
[CHCL]
is lit when the chuck is in the clamp state.
In this state, spindle rotation is possible in both automatic and manual
operations.
The status indicator
[CHCL]
is not lit when the chuck is in the unclamp state.
The chuck interlock function disables spindle 1 rotation if this indicator is not lit.
When chuck 1 (left) is selected with the head selection switch
(head 1), the
clamped status is indicated for chuck 1 (left).
When chuck 2 (right) is selected with the head selection switch
(head 2), the
clamped status is indicated for chuck 2 (right).
If automatic operation cannot be started, check whether or not this
indicator is lit.
After turning on of the power supply, the indicator is lit when the conditions
necessary for machine operation are arranged.
Machine operation is impossible unless this indicator is lit.
The fact that this indicator is lit means that the electrical system is
operating correctly.
Start machine operation only after making sure that the operation can
be started safely by checking the machine condition, cutting tool(s),
workpiece, working environment and program.
ERR
MRDY
X
Z
TRCL
CHCL
STATUS
C
Y
2
C
Y
1
<Operation panel>
<Option panel>
ERR
NOTE
CHCL
1
2
NOTE
MRDY
NOTE