49
MSD Single-Axis Servo Drive Compact Operation Manual
ID no.: CA97555-001 Date:
04
/201
8
moog
5.4.1
Function of buttons T1 and T2
These buttons are used to activate the different menus and to control the corresponding
functions.
Button
Function
Comment
T1 (left)
Activation of menu (exit the device
status display)
Scrolling through the menus/sub-menus
Setting values - left segment display
(D1)
The button T1 can be held pressed for any
length of time because the display will only scroll
through the menu options for the corresponding
level. No settings will be changed.
T2 (right)
Selection of chosen menu
Setting values - right segment display
(D2)
The button T2 must
NOT
be held pressed for any
length of time because the display will change
from one menu level to the next within the menu
structure and then change the parameter that
is reached at the end. You should therefore
always release the button T2 after each change
in display.
T1 and T2
together
Menu level up
Accept selection
Acknowledge
After pressing T1 and T2 at the same time, the
value applied flashes for five second During this
time the save procedure can still be aborted by
pressing any button, without applying the value
set. Otherwise the new value will be saved after
five seconds
General
The time the button needs to be held pressed
until an action is executed, is approx.
1 second.
If there is no action by the user for a period of
60 seconds,
the display returns to the device
status display.
Table 5.6 Function of buttons T1 and T2
The following functions and displays are available:
y
Display of device states (see chapter "6.1 Device states")
The device state is displayed after switching on the control voltage. If no input is made via the
keypad for 60 seconds,
the display switches back to the device state.
y
Display of device error state (see chapter "6.2 Error indication")
If a device error occurs the display immediately switches to show the error code.
y
Parameter setting (indication "PA") (see section 5.4.3)
Resetting device parameters to their factory setting
y
Ethernet IP address setting (indication "IP") (see section 5.4.5)
Setting the Ethernet IP address and the subnet mask
y
Field bus settings (indication "Fb") (see section 5.4.6)
Setting e.g. the field bus addres
Содержание MSD C2
Страница 1: ...C2 to C5 2 0 A to 16 0 A MSD Servo Drive Operation Manual Single Axis Servo Drive Compact moog ...
Страница 8: ...8 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 16: ...16 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 44: ...44 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 54: ...54 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 66: ...66 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 71: ...71 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...