50
MSD Single-Axis Servo Drive Compact Operation Manual
ID no.: CA97555-001 Date:
04
/201
8
moog
5.4.3
Parameter menu (PA)
On the Parameter menu the device settings can be reset to the factory setting.
Menu level
Param-
eter
Value
range
Meaning
Explanation
1
2
PA
Pr
-
-
Parameter reset
Reset device settings to factory setting
Table 5.8 Parameter menu
5.4.4
Error numbers
A failed user action is indicated by an error message. The message consists of an
alternating display of "Er" and the error number.
NOTE:
The error messages displayed during user input should not be confused with
drive error messages. For detailed information on the error codes and on
error management refer to the "MSD
Servo Drive Device Help".
Table 5.9 Error numbers
5.4.2
Display
The following table defines various displays and status information about the display.
Display
Meaning
Menu entries
(“PA“ in this case serves as an example, further possible entries see sections 5.4.5
and 5.4.6)
[flashing decimal points
Selected function in action
[two dashes]
Entry/function not available
[OK]
Action executed successfully, no errors
[Error]
Action via control unit
not
executed successfully,
“Er“ flashes alternately with error number
(see section 5.4.3)
Display device error,
“Er“ flashes alternately with error number and error location
(see
“MSD
Servo Drive Device Help“)
Numerical values
(“10” in this case serves as an example)
In the parameter menu (PA) error numbers are shown in
decimal
.
All other values are displayed in
hexadecimal
. In these cases the 10 displayed
would represent the decimal value 16.
Table 5.7 Meaning of display
NOTE:
If no input is made via the keyboar
d for a period of 60 s, the display r
eturns to
the device status display.
Error number
Meaning
00
01
02
03
04
05
17
18
19
20
21
File system no error
File system any file system error
File system command rejected
File system function parameter invalid File system
create file error
File system open file error
Parameter reset to factory settings failed Parameter
write access failed
Save parameter data set non volatile failed Not all
parameters written
Error while reset to factory settings
Содержание MSD C2
Страница 1: ...C2 to C5 2 0 A to 16 0 A MSD Servo Drive Operation Manual Single Axis Servo Drive Compact moog ...
Страница 8: ...8 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 16: ...16 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 44: ...44 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 54: ...54 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 66: ...66 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...