27
MSD Single-Axis Servo Drive Compact Operation Manual
ID no.: CA97555-001 Date:
04
/201
8
moog
NOTE
Suitable measures must generally be applied to provide adequate cable
protection.
DANGER
Risk of injury due to electrical power!
•
Carelessness will result in serious injuries or death.
When the mains voltage is switched on at terminal X3 and there is no control supply
(+24
V DC at
X2), a dangerous voltage is present on the device with no visual signal on the display or acoustic
indication by fan noise. If visible in the installed state, LED H1 (see Figure 4.1) indicates whether
voltage is present on the device. Even if H1 is completely off, X1 must be checked to ensure no
electrical power is present.
NOTE
The start-up current for the supply voltage for the C2 to C5 may be two to
three times the operation current.
4.8 Connection of the supply voltages
The supply of power to the MSD Single-Axis Servo Drive Compact is separate for the
control and power sections. The control supply should always be connected
firs
, so
that the device parameters can be set with Moog
D
rive
A
DministrAtor
5
and, above all, the
device set to the correct supply for the power section.
CAUTION!
Damage to the device due to incorrect operation!
•
Carelessness can cause damage to the device.
Only when the mains voltage has been pre-set in the device firmware and the device has been
restarted (if the mains voltage or switching frequency has been changed) may the mains power
supply for the supply for the power section be activated.
4.8.1
Connection of contr
ol supply (+24 V DC)
+
+
+
X2
X3
L1
X2
X3
L1
external power
supply
Device 1 (e.g. C2)
Device 2 (e.g. C2)
next
s
ervo
d
rive
24 V DC ±10 %
maximum 10 A gG
Figure 4.15 Connection of control supply MSD Single-Axis Servo Drive Compact
Control supply (Specification)
Control
supply
X2/+
X2/-
•
U
V
= +24 V DC ±10 %,
stabilised and filtered
•
I
V
= 2 A (C2 to C5)
•
Internal polarity reversal protection
•
The power supply unit used must have a safe and reliable isolation against
the mains system acc. to
EN 50178 or
IEC/
EN 61800-5-1
Table 4.5 Specification of control supply MSD Single-Axis Servo Drive Compact
Содержание MSD C2
Страница 1: ...C2 to C5 2 0 A to 16 0 A MSD Servo Drive Operation Manual Single Axis Servo Drive Compact moog ...
Страница 8: ...8 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 16: ...16 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 44: ...44 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 54: ...54 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 66: ...66 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...
Страница 71: ...71 MSD Single Axis Servo Drive Compact Operation Manual ID no CA97555 001 Date 04 2018 moog ...