![Monroe Electronics DASDEC-II Скачать руководство пользователя страница 128](http://html1.mh-extra.com/html/monroe-electronics/dasdec-ii/dasdec-ii_user-manual_1828808128.webp)
One-Net/DASDEC User Manual
5-99
v3.0 | r1016
selections can be made using the CTRL key when making selections or they can be
added one at a time.
Current FIPS locations for One-Button DEMO Decode/Forwarding Test
Contains a list of FIPS codes intended for use with the Demo/Practice Warning test.
Each FIPS code has a pull-down menu for subdividing the FIPS location. The default
value is ‘All’. To delete a FIPS code from this list, click the corresponding
Remove
button.
Roll EAS station IDs three times
When checked, will roll EAS station ID three times. Left unchecked, EAS station ID will
roll once.
Preempt an in-progress alert announcement as a test
Check to enable. Make sure blocking during in-progress alert announcements is
disabled to run this test.
When DMO event is forwarded, forward live and bypass criteria (like an EAN, NPT)
Will simulate a national live alert.
EAS Origination (ORG) Codes
Displays a list of available EAS Origination (ORG) Codes. Select one of the codes by
clicking on it. This code will be used with the Demo/Practice EAS message.
Select Alert Audio Message
This selector allows an audio message file to be selected for the audio message portion
of the DMO alert.
Under the Select Alert Audio Message pull-down menu, a hyperlink labeled
To upload
audio files goto Setup Audio Output Levels and Tests
is provided to go to the
Setup >
Audio Output Levels/Tests
screen where users can upload and listen to the available
audio files (See the Audio Setup section of this chapter).
A link labeled
To Run Demo alert goto Decoder Incoming/Decoded Alerts
is provided
to go to the
Incoming/Decoded Alerts
screen within the
Alert Events
tab. Demo/
Practice alerts may be added and forwarded from this location.
NET ALERT SETUP
There are up to six sub-tabs within the
Setup > Net Alerts
page. Valid license keys will
display the appropriate sub-tabs.
Sub-Tab
Description
DVS168
Configuration of a single DVS-168/EARS client for sending EAS
alerts..
EAS NET
Provides a variety of methods to exchange data (including
alert notifications) between EAS devices and other remote
hosts. Includes support for multiple DVS-168 network clients.
This sub-tab replaces the DVS168 sub-tab (above) when
enabled.
Requires valid EAS NET and Encoder license keys
.
CAP Decode
Enables communication with Common Alerting Protocol (CAP)
servers such as FEMA’s IPAWS.
Requires a valid CAP Plus
license key
.