EtherNet/IP™ CIP Safety™ IP67 HarshIO 600
46
IP67 Safety Digital I/O Modules
EMC
Standard
Comment
Emitted interference
EN 61000-6-4
Class A (Industrial area)
Noise immunity zone B
EN 61000-6-2
Industrial area
EN 61000-4-2
ESD
8kV air discharge
6kV contact discharge
EN 61000-4-3
High-frequency electromagnetic field
80MHz
… 1000MHz, 20V/m, 80% AM (1kHz)
1.4GHz ... 2.0GHz, 6V/m, 80% AM (1kHz)
2GHz ... 2.7GHz, 2V/m, 80% AM (1kHz)
EN 61000-4-6
Conducted disturbances, induced by radio
150kHz
… 80MHz, 10V, 80% AM (1kHz)
EN 61000-4-4
Burst
+/- 3kV 5/50 ns, 5 kHz on power ports
+/- 2kV 5/50 ns, 5 kHz on I/O ports
+/- 2kV 5/50 ns, 5 kHz communication ports
EN 61000-4-5
Surge
1kV line to line, 2kV line to earth on power ports
2kV line to line on I/O ports
2kV line to earth on communication ports
Warning!
Molex devices comply with EU directives and conform (DoC) to the related EMC
standards so that they can be easily integrated into other devices or machines.
However, EMC compliance of the whole system remains under system builder
responsibility.