EtherNet/IP™ CIP Safety™ IP67 HarshIO 600
21
IP67 Safety Digital I/O Modules
Product features
EtherNet/IP CIP Safety HarshIO main features include:
Safety Inputs
o
To connect safety devices, such as emergency stop push buttons, gate switches, and safety light
curtains.
o
Single or dual channel modes supported.
o
Dual-channel mode evaluates consistency between two input signals (channels), which allows
use of the module for Safety Category 3 and 4. The time of a logical discrepancy between two
channels can be monitored using a discrepancy time setting.
o
Each safety input has its own associated test output to check external wiring short-circuit.
o
Independently adjustable ON and OFF delay are available per channel.
Test Outputs
o
Separate test outputs are provided for external short circuit detection of a safety input.
o
Power (24 V) can be supplied to devices, such as safety sensors.
o
Test outputs can be configured as standard non-safe outputs.
o
2 test outputs can be used for broken wire detection of a muting lamp.
Safety Outputs or Bipolar Safety Outputs
o
Up to 1A for safety outputs and up to 2A for bipolar per output point.
o
Dual-channel mode evaluates consistency between two output signals (channels).
o
Safety outputs can be pulse tested to detect field wiring shorts to 24 VDC.
o
Bipolar safety outputs use pulse testing to detect a short to 24 VDC on the safety sourcing output,
and a short to 0VDC on the safety sinking output.
I/O Safety RPI with up to 10ms cycle time
IP67 rated enclosure that when properly installed provides protection against the ingress of dust, water
Integrated 2-port unmanaged Ethernet switch with cross-over and DLR capability
Isolated grounding to able to use 2 separate power supplies to energize the module logic/inputs and
outputs.
Protective earth (for power supplies)
Functional earth (for Ethernet connectors)
Diagnostic visible LEDs
Easy commissioning via Molex Safety Network Configuration Tool (SNCT)
On-board memory key (Window or M8 versions) allowing to store module configuration and perform
replacement in few minutes without any special tool or re-commissioning.
3 rotary switches to set IP address
Ultra-Lock M12 connectivity
HarshIO safety modules with Micro-Change
®
(M12) ports accept both
threaded cordsets and Molex Ultra-
Lock™ system.
Ultra-
Lock™ connection System! The fastest, easiest and most secure
connection ever designed. Ultra-
Lock™ technology is designed for
higher performance and reliability.
Discover how the push-to-lock technology of the Ultra-Lock connection
system can eliminate the downtime, increase the productivity and lower
the costs. More information visit:
www.molex.com
.
Содержание TCDEC-8B4B-D1U-G8
Страница 141: ...EtherNet IP CIP Safety IP67 HarshIO 600 141 IP67 Safety Digital I O Modules Select Yes Select Yes ...
Страница 166: ...EtherNet IP CIP Safety IP67 HarshIO 600 166 IP67 Safety Digital I O Modules ...
Страница 181: ...EtherNet IP CIP Safety IP67 HarshIO 600 181 IP67 Safety Digital I O Modules 14 Certifications ...
Страница 182: ...EtherNet IP CIP Safety IP67 HarshIO 600 182 IP67 Safety Digital I O Modules TUV Certificate ...