EtherNet/IP™ CIP Safety™ IP67 HarshIO 600
99
IP67 Safety Digital I/O Modules
Give a Name and set the module IP address that has been discovered by RSLinx.
RSLogix software creates automatically a Safety Network Number (also called SNN). The Safety Network
Number is a unique identifier of 48-bit number to prevent the acceptance of connection requests that have
been misdirected. This is to ensure that every module on the safety network can be uniquely identified.
Warning!
Safety controllers (Originator) that have an “Automatic” SNN setting feature should only
use that feature when the safety system is not being relied upon