EtherNet/IP™ CIP Safety™ IP67 HarshIO 600
34
IP67 Safety Digital I/O Modules
Notes!
Safety Sourcing outputs should not be used to provide power to a device
or sub-system whom the resistive and capacitive load could vary during
operation.
Warning!
Be careful of the response time of the output device to prevent any malfunction
because of pulse test.
Safety No Pulse Test
- The output is used without pulse test.
Note!
In this mode, diagnostics are done on the output. When a sourcing output is
switched off, the measured state can be different to the expected one due to the
capacitive load of the connected equipment. HarshIO have been design to control
a wide range of equipment by using an active discharge circuit. When a sourcing
output is switched off, if a residual voltage is present, a 50mA current is clamped
during 2ms.
M12 pining and wiring of the safety sourcing outputs:
1: 24 VDC (powered from UL)
2: Safe Output #1 (OUT1)
3: Ground Output (UL GND)
4: Safe Output #0 (OUT0)
5: Ground Output (UL GND)
Note!
The maximum current available on the Pins #1 (24 VDC) of the 2 Output sourcing ports
is 3.5A.
1
1
2
3
4
5
External Load
OUT0
OUT1
GND
External Load
GND
24V
Содержание TCDEC-8B4B-D1U-G8
Страница 141: ...EtherNet IP CIP Safety IP67 HarshIO 600 141 IP67 Safety Digital I O Modules Select Yes Select Yes ...
Страница 166: ...EtherNet IP CIP Safety IP67 HarshIO 600 166 IP67 Safety Digital I O Modules ...
Страница 181: ...EtherNet IP CIP Safety IP67 HarshIO 600 181 IP67 Safety Digital I O Modules 14 Certifications ...
Страница 182: ...EtherNet IP CIP Safety IP67 HarshIO 600 182 IP67 Safety Digital I O Modules TUV Certificate ...