APPENDIX B. ELECTRICAL AND DATA CONNECTIONS
ISA-4001CR INVERTER POWER SUPPLY
B-6
990-364
PIN
NUMBER
SIGNAL NAME
SIGNAL DESCRIPTION
46
Stage 2
Stage 2 input terminal. When this signal is present (connected to pin
50), welding commences according to the schedule selected at the
binary inputs (pins 31 through 37).
47
Retraction
Retraction Valve input terminal. When this input is present
(connected to pin 50), The Retraction Valve output signal is applied
if the unit is not welding.
48
Backstep
Backstep input terminal. When this signal is present (connected to
pin 50) while the Successive function is being performed, the
Schedule # returns to the previous schedule. If the signal is held for
1.5 seconds or more, the Schedule # returns to the first schedule
49 Spare
50
Common
Common terminal for terminals 35-37 and 45-49.
51 Proportional
Valve
Ground
52 Proportional
Valve
Optional configuration
Provides 0 –10 VDC variable signal to an external proportional valve
53, 54
Cable Error
One side is connected to chassis ground. The other side is connected
to the shield on the weld transformer primary cable. The shield is
not connected at the transformer end. If a device, such as a robot,
begins to damage the cable, it will touch the shield first, thereby
shorting the cable error connections. The unit will stop welding and
generate a cable error signal.
56, 57, 58,
59, 60, 61, 62
User Spare Terminals
Terminals available for use without Isolation Contactor option. No
internal signals are connected to these terminals.
See NOTES:
63,64
Current Coil input
Optional attachment of built-in current coil of welding transformer
equipped as such
NOTES:
x
When the Isolation Contactors option is
not
installed, pins 56 through 59 are User Spare pins.
x
When the Isolation Contactors option
is
installed, the pin assignments are shown below.
PIN
NUMBER
SIGNAL NAME
SIGNAL DESCRIPTION
55
24V out
+24 VDC
56
Contactors
To close internal contactors (2), connect pin 56 (Contactors) to pin
55 (24V out).
57 Not
used
58 Not
used
59 Not
used
Содержание ISA Series
Страница 16: ...CHAPTER 1 SYSTEM DESCRIPTION ISA 4001CR INVERTER POWER SUPPLY 1 4 990 364 ...
Страница 22: ......
Страница 30: ......
Страница 44: ......
Страница 48: ......
Страница 62: ......
Страница 76: ......
Страница 87: ...APPENDIX C SYSTEM TIMING ISA 4001CR INVERTER POWER SUPPLY 990 364 C 11 Pulsation Pulsation ...
Страница 108: ......
Страница 112: ......
Страница 114: ......
Страница 116: ......
Страница 118: ......