64
4 Specifications, External Dimensions and Terminal Layout (Main Units)
4.5 Performance Specifications
FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
Item
Performance
Number of
input/output
points
(1)Extension-
combined number
of input points
248 points
(3) total
points
(1) + (2)
≤
(3) total number of points is
256 or less.
(2)Extension-
combined number
of output points
248 points
(4)Remote I/O number
of points (CC-Link)
224 points or less
Either the CC-Link or AS-i master can be
used (the two cannot be used
concurrently)
(4)Remote I/O number
of points (AS-i)
248 points or less
(3) + (4) total number
of points
384 points or less
Input/output
relay
Input relay
X000 to X367
248 points The device numbers are octal.
The total number of input and output
points is 256.
Output relay
Y000 to Y367
248 points
Auxiliary relay
For general
[changeable]
M0 to M499
500 points
The retentive status can be changed by
parameter settings.
For keeping
[changeable]
M500 to M1023
524 points
For keeping
[fixed]
M1024 to
M7679
6656 points
−
For special
M8000 to
M8511
512 points
−
State
Initial state
(for general)
[changeable]
S0 to S9
10 points
The retentive status can be changed by
parameter settings.
For general
[changeable]
S10 to S499
490 points
For keeping
[changeable]
S500 to S899
400 points
For annunciator
(For keeping)
[changeable]
S900 to S999
100 points
For keeping
[fixed]
S1000 to S4095
3096 points
−
Timer (on-
delay timer)
100 ms
T0 to T191
192 points 0.1 to 3,276.7 sec
100 ms
[for subroutine/
interruption
subroutine]
T192 to T199
8 points 0.1 to 3,276.7 sec
10 ms
T200 to T245
46 points 0.01 to 327.67 sec
1 ms accumulating
type
T246 to T249
4 points 0.001 to 32.767 sec
100 ms accumulating
type
T250 to T255
6 points 0.1 to 3,276.7 sec
1 ms
T256 to T511
256 points 0.001 to 32.767 sec
Counter
Increment for general
(16 bits) [changeable]
C0 to C99
100 points Counting from 0 to 32,767
The retentive status can be changed by
parameter settings.
Increment for keeping
(16 bits) [changeable]
C100 to C199
100 points
Both directions for
general (32 bits)
[changeable]
C200 to C219
20 points Counting from -2,147,483,648 to
+2,147,483,647
The retentive status can be changed by
parameter settings.
Increment for keeping
(32 bits) [changeable]
C220 to C234
15 points
Содержание FX2-16E series
Страница 2: ......
Страница 8: ... 6 Safety Precautions Read these precautions before use MEMO ...
Страница 508: ...FX3U Series Programmable Controllers User s Manual Hardware Edition 500 C Character code C 1 ASCII Code Table MEMO ...
Страница 510: ...502 FX3U Series Programmable Controllers User s Manual Hardware Edition D Discontinued models MEMO ...
Страница 519: ......