FX
3U
Series Programmable Controllers
User's Manual - Hardware Edition
78
5 Version Information and Peripheral Equipment Connectability
5.2 Programming Tool Applicability
3. FX-30P
FX-30P is applicable to FX
3U
PLCs from the following version.
5.2.2
In case of programming tool (version) not applicable
Inapplicable programming tools can programme by setting alternative model.
1. Alternative model setting
2. Contents of restrictions
• Programming is enabled only in the function ranges such as instructions, device ranges and program sizes
available in a PLC selected as the alternative model.
• When "FX3UC" is selected, programs and functions of applied instructions added from the corresponding
version are different.
• Change the parameters such as the memory capacity and file register capacity using a programming tool
allowing selection of "FX3U(C)" or "FX3UC".
5.2.3
Program transfer speed and programming tools
1. RS-422/RS-232C/USB communication
The FX
3U
PLC can write and read programs and perform monitoring at 115.2 kbps through RS-422/RS-232C/
USB communication.
1) 115.2 kbps supported programming tools
GX Works2 (Ver. 1.08J or later), GX Developer (Ver. 8.18U or later), FX-30P (Ver. 1.00 or later)
2) 115.2 kbps supported interfaces
- Standard built-in port or expansion board FX
3U
-422-BD for RS-422
When the RS-232C/RS-422 converter FX-232AWC-H or USB/RS-422 converter FX-USB-AW is
connected.
- Expansion board FX
3U
-232-BD for RS-232C
- Special adapter FX
3U
-232ADP(-MB) for RS-232C
- Expansion board FX
3U
-USB-BD for USB
3) In programming tools not supporting 115.2 kbps
Communication is executed at 9,600 or 19,200 bps.
FX
3U
PLC version
Model name
Applicable
FX-30P version
Remarks
Before Ver. 2.41
FX-30P
Ver. 1.00 or later
Model selection: Not selected (Online mode)
Model selection: FX3U(C) (Offline mode)
Ver. 2.70
Ver. 1.20 or later
Model to be programmed
Model to be set
Priority High
→
Low
FX
3U
PLC
FX
3U(C)
→
FX
3UC
→
FX
2N
→
FX
2