FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
63
4 Specifications, External Dimensions and Terminal Layout (Main Units)
4.5 Performance Specifications
1
Introducti
on
2
Features
and
Par
t Names
3
Product
Introduc
tion
4
Sp
eci
fic
ati
ons
5
V
ers
ion and
Peri
ph
er
al
D
evices
6
S
yst
em
C
onfi
guration
7
Input/Ou
tput
No
s., Un
it No
s.
8
Inst
allati
on
9
Prep
arati
on an
d
Pow
er Supp
ly
Wi
rin
g
10
Input W
iring
4.5
Performance Specifications
The performance specifications are common to FX
3U
Series PLCs.
*1.
Storage of symbolic information is supported in Ver. 3.00 or later. The writable symbolic information
capacity varies depending on the parameter setting contents and memory cassette type. Refer to
Section 21.3 and the GX Works2 Version 1 Operating Manual (Common) for symbolic information
capacity.
*2.
Supported in Ver. 3.00 or later.
Item
Performance
Operation control system
Stored program repetitive operation system (dedicated LSI) with
interruption function
Input/output control system
Batch processing system (when END instruction is executed)
Input/output refresh instruction and pulse catch function are provided.
Programming language
Relay symbol step-ladder system (SFC notation possible)
Program
memory
Max. memory capacity
64000-step (2k-, 4k-,8k-, 16k- or 32k-step memory can be selected by
parameter settings.)
Comments and file registers can be created in the program memory by
parameter settings.
• Comments: Up to 6350 points (50 points/500 steps)
• File registers: Up to 7000 points (500 points/500 steps)
Built-in memory
capacity/type
64000-step (Symbolic information can be stored.
*1
)/
RAM (backed up by built-in lithium battery)
• Battery life: Approx. 5 years (For details refer to Subsection 22.3.1)
Memory cassette
(Option)
Flash memory (The max. memory capacity varies depending on the
model of the memory cassette.)
• FX
3U
-FLROM-1M
*2
: 64000 steps (no loader function, symbolic
information can be stored in the dedicated area
(1300 kB).)
• FX
3U
-FLROM-64L: 64000 steps (loader function, symbolic
information can be stored.
*1
)
• FX
3U
-FLROM-64:
64000 steps (no loader function, symbolic
information can be stored.
*1
)
• FX
3U
-FLROM-16:
16000 steps (no loader function, symbolic
information can be stored.
*1
)
Max. allowable write: 10,000 times
Writing function
during running
Provided (Program can be modified while the PLC is running.)
→
For the writing function during running,
refer to Subsection 5.2.5.
Password protection
Provided (with entry code function)
Real-time
clock
Clock function
Built-in
1980 to 2079 (with correction for leap year)
2- or 4-digit year, accuracy within
±
45 seconds/month at 25
°
C
Kinds of
instructions
Basic instructions
Ver. 2.30 or later
• Sequence instructions: 29
• Step-ladder instructions: 2
Former than Ver. 2.30
• Sequence instructions: 27
• Step-ladder instructions: 2
Applied instructions
218 kinds, 497 instructions
Processing
speed
Basic instructions
0.065
µ
s/instruction
Applied instructions
0.642
µ
s to several hundred
µ
s/instruction
Содержание FX2-16E series
Страница 2: ......
Страница 8: ... 6 Safety Precautions Read these precautions before use MEMO ...
Страница 508: ...FX3U Series Programmable Controllers User s Manual Hardware Edition 500 C Character code C 1 ASCII Code Table MEMO ...
Страница 510: ...502 FX3U Series Programmable Controllers User s Manual Hardware Edition D Discontinued models MEMO ...
Страница 519: ......