FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
219
11 Use of High-speed Counters (C235 to C255)
11.9 Calculation of Response Frequency and Overall Frequency
11
Hi
gh
-Speed
Counters
12
O
utput W
iri
ng
13
W
iri
ng for
V
ari
ous
Us
es
14
Te
st R
un,
Mai
nten
ance,
T
roubl
es
hooti
ng
15
IInput/Output
Pow
ered
Exte
nsi
on U
nit
s
16
Input/O
utput
Extens
ion
Bl
ock
s
17
Extension
Power Suppl
y
Un
it
18
Other Extens
ion
Uni
ts an
d
Opti
ons
19
D
isplay M
od
ule
20
Te
rminal
Bl
oc
k
1) Calculation of overall frequency
The overall frequency is calculated by the high-speed comparison instruction used in the program based
on the above table.
Overall frequency
≥
Sum of "response frequency of high-speed counter
×
Magnification for
calculation of overall frequency"
2) Example of calculation
When only HSZ instruction is used six times in a program, the frequency is calculated by the formulas
shown in the "Only HSZ instruction" column in the above table.
2. When FX
3U
Series special function units/blocks and analog special adapters are used
*1.
When an index register is added to a counter number specified by HSCS, HSCR, HSZ or HSCT
instruction, all hardware counters are switched to software counters.
*2.
The high-speed counters C244(OP) and C245(OP) cannot count signals of 10 kHz or more.
High-speed counter No. to be
used
Input
frequency
Calculation of max.
response frequency
Magnification
for
calculation of
overall
frequency
Instruction
to be used
C237
Operation as
software counter
30kHz
40 - 6(times) = 34kHz
×
1
HSZ instruc-
tion is used
six times.
C241
Software counter
20kHz
40 - 6(times) = 34kHz
×
1
C253(OP)
[
4 edge count
]
4kHz
{
40 - 6(times)
}
/ 4 = 8.5kHz
×
4
Counter type
Counter
Nos.
Software
counters
with
HSCS,
HSCR,
HSZ or
HSCT
instructio
n *1
Magni-
fication
for
calcu-
lation
of
overall
frequ-
ency
Response frequency and overall frequency depending on
conditions of instruction to be used
Neither HSZ nor
HSCT instruction
Only HSCT
instruction
Only HSZ instruction
Both HSZ and HSCT
instructions
Max.
response
frequency
(kHz)
Overall
frequency
(kHz)
Max.
response
frequency
(kHz)
Overall
frequency
(kHz)
Max.
response
frequency
(kHz)
Overall
frequency
(kHz)
Max.
response
frequency
(kHz)
Overall
frequency
(kHz)
1-phase
1-count input
C241,
C242,
C243,
C244,
C245
C235,
C236,
C237,
C238,
C239,
C240
×
1
30
60
25
50
30 -
(number of
instruc-
tions)
*2
50 - 1.5
×
(number of
instruc-
tions)
25 -
(number of
instruc-
tions)
*2
50 - 1.5
×
(number of
instruc-
tions)
−
C244(OP),
C245(OP)
×
1
10
10
1-phase
2-count input
C247,
C248,
C249,
C250
C246,
C248(OP)
×
1
30
25
2-
phase
2-
count
input
1 edge
count C252,
C253
(OP),
C254,
C255
C251,
C253
×
1
30
25
4 edge
count
×
4
7.5
6.2
(30 -
number of
instruc-
tions) / 4
(25 -
number of
instruc-
tions) / 4
1) The overall frequency is calculated as shown below because HSZ instruction is
used six times.
Overall frequency = 80 - 1.5
×
6 = 71kHz
2) The sum of the response frequencies of the high-speed counters used is
calculated as shown below.
"30kHz
×
1[C237]" + "20kHz
×
1[C241]" + "4kHz
×
4[C253(OP)]" = 66kHz
≤
71kHz
Содержание FX2-16E series
Страница 2: ......
Страница 8: ... 6 Safety Precautions Read these precautions before use MEMO ...
Страница 508: ...FX3U Series Programmable Controllers User s Manual Hardware Edition 500 C Character code C 1 ASCII Code Table MEMO ...
Страница 510: ...502 FX3U Series Programmable Controllers User s Manual Hardware Edition D Discontinued models MEMO ...
Страница 519: ......