FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
343
16 FX2N-8/16E*-*(Input/Output Extension Blocks)
16.10 FX2N-8EYR, FX2N-16EYR (Relay Output)
11
Hi
gh
-Speed
Counters
12
O
utput W
iri
ng
13
W
iri
ng for
V
ari
ous
Us
es
14
Te
st R
un,
Mai
nten
ance,
T
roubl
es
hooti
ng
15
IInput/Output
Pow
ered
Exte
nsi
on U
nit
s
16
Input/O
utput
Extens
ion
Bl
ock
s
17
Extension
Power Suppl
y
Un
it
18
Other Extens
ion
Uni
ts an
d
Opti
ons
19
D
isplay M
od
ule
20
Te
rminal
Bl
oc
k
16.10 FX
2N
-8EYR, FX
2N
-16EYR (Relay Output)
16.10.1 Product specifications
The generic specifications are identical to the main unit specifications.
→
Refer to Section 4.1 for generic specifications.
For external wiring, refer to the following chapter.
→
Refer to Chapter 12 for output wiring.
1. Power supply specifications
2. Weight and Other specifications
3. Output specifications (Relay output type)
Item
FX
2N
-8EYR
FX
2N
-16EYR
Product type
FX
2N
extension block
Rated voltage
24V DC (supplied from main unit and input/output powered extension unit)
Item
FX
2N
-8EYR
FX
2N
-16EYR
MASS (Weight)
0.2 kg (0.44lbs)
0.3 kg (0.66lbs)
Other
• The extension cable is already connected to the extension block.
• Accessories: Label for indication of input/output number
• The DIN46277 rail (width: 35 mm (1.38")) or direct installation.
Item
FX
2N
-8EYR
FX
2N
-16EYR
Output points
8 points
16 points
Connection unit
Vertical terminal block (M3 screws)
Output unit
Relay
External power supply
250V AC 30V DC or less
Output circuit insulation method
Mechanical insulation
Indication of output operation
Supplying power to the relay coil will light the LED indicator lamp on panel.
Maximum load
Resistance
load
2 A/point
The total resistance load current per common should be as follows:
• 4 output points/common: 8A or less
• 8 output points/common: 8A or less
Inductive load
80 VA
→
For the product life, refer to Subsection 4.4.2.
→
For cautions on external wiring, refer to Subsection 12.2.4.
Open circuit leakage current
−
Minimum load
5V DC, 2 mA (reference values)
Response time
OFF
→
ON
Approx. 10 ms
ON
→
OFF
Approx. 10 ms
Output circuit diagram
A common number applies to the of [COM ].
Load
DC power
supply
AC power
supply
Fuse
Y
COM
Fuse
Y
COM
Load
Содержание FX2-16E series
Страница 2: ......
Страница 8: ... 6 Safety Precautions Read these precautions before use MEMO ...
Страница 508: ...FX3U Series Programmable Controllers User s Manual Hardware Edition 500 C Character code C 1 ASCII Code Table MEMO ...
Страница 510: ...502 FX3U Series Programmable Controllers User s Manual Hardware Edition D Discontinued models MEMO ...
Страница 519: ......