FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
37
2 Features and Part Names
2.2 Names and Functions of Parts
1
Introducti
on
2
Features
and
Par
t Names
3
Product
Introduc
tion
4
Sp
eci
fic
ati
ons
5
V
ers
ion and
Peri
ph
er
al
D
evices
6
S
yst
em
C
onfi
guration
7
Input/Ou
tput
No
s., Un
it No
s.
8
Inst
allati
on
9
Prep
arati
on an
d
Pow
er Supp
ly
Wi
rin
g
10
Input W
iring
When the terminal block covers are open
When the display module (FX
3U
-7DM) is installed
[12]
Operation status display LEDs
The operation status of the PLC can be checked with the LEDs.
The LEDs turn off, light and flash according to the following table.
→
For details on the operation status, refer to Section 14.5.
[13]
Output display LEDs (red)
When an output terminal (Y000 or more) is turned on, the corresponding
LED is lit.
[14]
Power supply terminal
Connect the power supply to the main unit.
[15]
Protective terminal
covers
A protective terminal cover (refer to the following drawing) is fitted to the lower
stage of each terminal block. (FX
3U
-
{{
M /ES(S), DS(S), and UA1 are equipped.)
The cover prevents fingers from touching terminals, thereby improving safety.
[16]
Input (X) terminals
Wire switches and sensors to the terminals.
[17]
Terminal block
mounting screws
If the main unit must be replaced, loosen the screws (slightly loosen the left and
right screws), and the upper part of the terminal block can be removed. (On FX
3U
-
16M , the terminal block cannot be removed.)
[18]
Terminal names
The signal names for power supply, input and output terminals are shown.
[19]
Output (Y) terminals
Wire loads (contactors, solenoid valves, etc.) to be driven to the terminals.
[20]
Display module (FX
3U
-7DM)
The display module (option) can be installed.
[21]
Top cover (accessory to FX
3U
-
7DM)
A square hole is made so that the display module can be seen. Replace
the original top cover with this cover.
LED name
Display color
Description
POWER
Green
On while power is on the PLC.
RUN
Green
On while the PLC is running.
BATT.V
Red
Lights when the battery voltage drops.
ERROR
Red
Flashing when a program error occurs.
Red
Lights when a CPU error occurs.
FX
3U
-48MR/ES
FX
3U
-48M
FX
3U
ERROR
RUN
BATT
POWER
R
0
3
1
2
IN
OUT
6
4
5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
0
3
1
2
6
4
5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
Y12
Y10
Y16
Y14
Y22
Y20
Y26
COM5
COM1
Y24
Y6
Y4
Y2
Y0
Y7
Y11
Y13
Y5
COM2
Y3
Y1
COM3
Y15
Y17
COM4
Y23
Y25
Y27
Y21
X5
X0
X1
X2
X3
X7
X11
X13
X4
0V
S/S
N
24V
X6
X10
X12
X14
X16
X20
L
X27
X23
X25
X15
X17
X21
X24
X26
X22
FX
3U
-48MR/ES
FX
3U
-48M
FX
3U
ERROR
RUN
BATT
POWER
R
0
3
1
2
IN
OUT
6
4
5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
0
3
1
2
6
4
5
21
7 20
24
22 23
26
25
27
Y12
Y10
Y16
Y14
Y22
Y20
Y26
COM5
COM1
Y24
Y6
Y4
Y2
Y0
Y7
Y11
Y13
Y5
COM2
Y3
Y1
COM3
Y15
Y17
COM4
Y23
Y25
Y27
Y21
X5
X0
X1
X2
X3
X7
X11
X13
X4
0V
S/S
N
24V
X6
X10
X12
X14
X16
X20
L
X27
X23
X25
X15
X17
X21
X24
X26
X22
[14] Power supply terminal
[16] Input (X) terminals
[19] Output (Y) terminals
[17] Terminal block mounting screws
[18] Terminal names
[17] Terminal block mounting screws
[15] Protective terminal covers
FX
3U
-48MR/ES
FX
3U
-48M
FX
3U
ERROR
RUN
BATT
POWER
R
0
3
1
2
IN
OUT
6
4
5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
0
3
1
2
6
4
5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
Y12
Y10
Y16
Y14
Y22
Y20
Y26
COM5
COM1
Y24
Y6
Y4
Y2
Y0
Y7
Y11
Y13
Y5
COM2
Y3
Y1
COM3
Y15
Y17
COM4
Y23
Y25
Y27
Y21
X5
X0
X1
X2
X3
X7
X11
X13
X4
0V
S/S
N
24V
X6
X10
X12
X14
X16
X20
L
X27
X23
X25
X15
X17
X21
X24
X26
X22
FX
3U
ERROR
RUN
BATT
POWER
R
0
3
1
2
IN
OUT
6
4
5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
0
3
1
2
6
4
5
21
7 20
24
22 23
26
25
10 11
13
12
16
14 15
17
27
Y12
Y10
Y16
Y14
Y22
Y20
Y26
COM5
COM1
Y24
Y6
Y4
Y2
Y0
Y7
Y11
Y13
Y5
COM2
Y3
Y1
COM3
Y15
Y17
COM4
Y23
Y25
Y27
Y21
X5
X0
X1
X2
X3
X7
X11
X13
X4
0V
S/S
N
24V
X6
X10
X12
X14
X16
X20
L
X27
X23
X25
X15
X17
X21
X24
X26
X22
[20] Display module (FX
3U
-7DM)
[21] Top cover (accessory to FX
3U
-7DM)
Содержание FX2-16E series
Страница 2: ......
Страница 8: ... 6 Safety Precautions Read these precautions before use MEMO ...
Страница 508: ...FX3U Series Programmable Controllers User s Manual Hardware Edition 500 C Character code C 1 ASCII Code Table MEMO ...
Страница 510: ...502 FX3U Series Programmable Controllers User s Manual Hardware Edition D Discontinued models MEMO ...
Страница 519: ......