FX
3U
Series Programmable Controllers
User’s Manual - Hardware Edition
47
3 Introduction of Products (Compliant with Overseas Standards)
3.1 List of Products (to be Connected) and Interpretation of Model Names
1
Introducti
on
2
Features
and
Par
t Names
3
Product
Introduc
tion
4
Sp
eci
fic
ati
ons
5
V
ers
ion and
Peri
ph
er
al
D
evices
6
S
yst
em
C
onfi
guration
7
Input/Ou
tput
No
s., Un
it No
s.
8
Inst
allati
on
9
Prep
arati
on an
d
Pow
er Supp
ly
Wi
rin
g
10
Input W
iring
4. High-speed input/output functions
: Compliance with standard or self-declaration : Not targeted
−
: Not applicable
* Please consult with Mitsubishi Electric for information on marine standard practices and the
corresponding types of equipment.
→
For more information on CE, UL and cUL, refer to Page 15 or later.
3.1.8
[I] Extension power supply unit
: Compliance with standard or self-declaration : Not targeted
−
: Not applicable
→
For more information on CE, UL and cUL, refer to Page 15 or later.
3.1.9
[J] Extension cables and connector conversion adapter
[K] Battery [L] Memory cassettes
: Compliance with standard or self-declaration : Not targeted
−
: Not applicable
*1.
When the extension cable (FX
0N
-30EC or FX
0N
-65EC) is used, use up to one cable for one system.
When an extension block is added, use FX
2N
-CNV-BC in addition to the cable.
These extension cables are unusable for FX
2N
-10GM and FX
2N
-20GM.
*2.
Products manufactured in and after June, 2005 will comply with the overseas standard.
*3.
Please consult with Mitsubishi Electric for information on marine standard practices and the
corresponding types of equipment.
→
For more information on CE, UL and cUL, refer to Page 15 or later.
Model name
Description
CE
UL
cUL
Marine
EMC
LVD
FX
3U
-4HSX-ADP
For differential line driver input (for high-speed counter)
*
FX
3U
-2HSY-ADP
For differential line driver output (for positioning output)
*
Model name
Description
Driving power
supply
CE
UL
cUL
Marine
EMC
LVD
FX
3U
-1PSU-5V
Extension power supply 5V DC 1A
100 to 240V AC
−
Classification
Model name
Description
CE
UL
cUL
Marine
EMC
LVD
Extension
cables
FX
0N
-65EC*
1
0.65m
(2’1")
These cables are used to mount input/output
extension units/blocks for FX
2N
and special
function units/blocks (except for the FX
2N
-
10GM and FX
2N
-20GM) away from the main
unit.
−
−
−
−
FX
0N
-30EC*
1
0.3m
(0’11")
−
−
−
−
FX
2N
-GM-65EC
0.65m
(2’1")
This cable is used when FX
2N
-10GM or
FX
2N
-20GM is mounted at the top of the
extension units/blocks.
−
−
−
−
Connector
conversion
adapter
FX
2N
-CNV-BC
Connector conversion adapter to connect input/
output extension blocks for FX
2N
and special function
blocks with model FX
0N
-30/65EC extension cable
−
−
−
−
Battery
FX
3U
-32BL
This battery backs up the following data.
• Program memory in built-in RAM
• Keep devices (battery backup devices)
• Results of sampling trace
• Time on clock
−
−
−
−
Memory
cassettes
FX
3U
-FLROM-
16
16k-step flash memory
−
*3
FX
3U
-FLROM-
64
64k-step flash memory
*
2
−
*3
FX
3U
-FLROM-
64L
64k-step flash memory (with transfer switch)
−
*3
FX
3U
-FLROM-
1M
64k-step flash memory
(There is an area dedicated to the storage of
symbolic information.)
−
*3
H
I
J
K
L
J
J
K
L
Содержание FX2-16E series
Страница 2: ......
Страница 8: ... 6 Safety Precautions Read these precautions before use MEMO ...
Страница 508: ...FX3U Series Programmable Controllers User s Manual Hardware Edition 500 C Character code C 1 ASCII Code Table MEMO ...
Страница 510: ...502 FX3U Series Programmable Controllers User s Manual Hardware Edition D Discontinued models MEMO ...
Страница 519: ......