-
-
'15 • HM-T-246
Error code
Remote control:
7-segment display:
LED
Green
Red
Heat pump
water heater
Keep
flashing
Content
E
E
Water pump anomaly ()
In case the motor rotates at anomously high speed
(Disable to control rotation speed or rotate at max speed)
-time
. Applicable Model
. Troubleshooting
All models
Diagnosis
Countermeasure
NO
YES
Is DC5V(Hi) or
DC1V(Lo) or lower detected
between 1P and 2P of CNPUM1
on the control PCB?
Is the
rotation speed of water
pump motor
normalized?
Is the
LED2 on control PCB
flashing?
FG signal for
rotaion speed
control is normal
Replace control PCB
Is the
rotation speed of water
pump motor
normalized?
Replace water pump PCB
NO
YES
NO
YES
YES
NO
FG signal for rotaion
speed control is
anomalous
Replace control P CB
It’s normal
Replace water pump motor
E nd
. E rror detection method
. Condition of error displayed
. P resumable cause
N ote:
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Содержание ESA30E-25
Страница 33: ... 15 HM T 246 Rear view Power transformer AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 69: ... 15 HM T 246 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 71: ... 15 HM T 246 0 WARNING CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 85: ... 15 HM T 246 4 3 System diagram 㪄㪈㪌㪄 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 91: ... 15 HM T 246 0 CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...