'15 • HM-T-246
7. Installation settings and Test run (Continue)
7. Installation settings and Test run
[TOP screen]
⇒
[Menu]
⇒
[Installation setting]
Service password is " " .
Set with [
▲
] [
▼
] buttons.
Tap Set to save.
Set the contact for the customer to
E nter the company name with up to
E nter the contact phone N o. with up
ask servicing
x -byte letters (0x -byte letters)
to x -byte letters
Tap Set to save.
Tap Set to save.
Move to the screen of a selected menu
After feeding water, please start [Water
After end of [Water pump test run],
pump test run] and purge air.
please start [P rimary setting of operation]
P lease refer to next page for detail
③
Service password input
①
TOP screen
⑨
Test run
⑧
E nter the P hone N o. of the contact
⑦
E nter the contact
⑪
P rimary setting of operation
⑩
Water pump test run
⑥
Company information
⑤
Installation date
④
Installation settings
Test run procedure
* When operating the unit initially, [Water pump test run] and [P rimary setting of operation] is required.
() P lease prepare for the test run according to instruction described on the installation manual of the heat pump water heater.
() Tap the Start button on the [
⑩
Water pump test run] screen of item [Installation settings and Test run].
Information
[Water pump test run] can be implemented with the Dip SW of the heat pump water heater as well.
P lease refer to the installation manual of the heat pump water heater for detail.
() Return to the TOP screen. When the [Water pump test run] starts, the message of " In water pump check operation" is displayed. (Screen
⑫
)
P lease purge air, and then open the drain valve and relief valve for the cylinder and check the water drain offFF continuously.
(If gurgling sound is heard or the drain is drawn offFF intermittently, purging air is not completed.)
() After the end of the [Water pump test run], please stop the water pump.
When pushing the Run/P ause switch, the [Water pump test run] is stopped.
() Tap the [Start] button on the [
⑪
P rimary setting of operation] screen of item [Installation settings and Test run].
Information
[P rimary setting of operation] can be implemented with the Dip SW of the heat pump water heater as well.
P lease refer to the installation manual of the heat pump water heater for detail.
() Return to the TOP screen. When the [P rimary setting of operation] starts, the message of " In P rimary operation" is displayed. (Screen
⑬
)
The actual hot water temperature during primary operation is diffFFerent from the displayed hot water temperature on the TOP screen,
because the heat pump water heater is operated by changing hot water temperatu re during prima
r
y operation.
() After the end of the [P rimary setting of operation], The heat pump water heater is paused and the message " In primary operation"
is disappeared and the message of " It is in operation by standby" is displayed. (Screen
⑭
)
If starting the operation to top up, pushing the Run/P ause switch.
However, if the primary operation does not completed within 0 minutes or this operation is stopped forcibly by pushing
Run/P ause switch before completion, this operation ends and the heat pump water heater pauses.
P lease restart [P rimary setting of operation] from the procedure ().
() After end of [P rimary setting of operation], please clean up strainers in the water circuit.
ge in the system and purge air again.
Caution
re, after the completion of the [Water pump test run] and
[P rimary setting of operation], please start operation to top up.
ry setting of operation], it does not start operation to top up, because the heat pump
water heater is pausing.
In case of staring operation, please push Run/P ause switch.
ressor may start operation for preventing water in the water pipe from
freezing.
⑫
In water pump check operation
⑬
In primary operation
⑭
After end of primary operation
PJZ012D103
②
Menu screen ()
②
Menu screen ()
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Содержание ESA30E-25
Страница 33: ... 15 HM T 246 Rear view Power transformer AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 69: ... 15 HM T 246 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 71: ... 15 HM T 246 0 WARNING CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 85: ... 15 HM T 246 4 3 System diagram 㪄㪈㪌㪄 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 91: ... 15 HM T 246 0 CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...