0
-
'15 • HM-T-246
. Applicable model
. Troubleshooting
All models
Diagnosis
Countermeasure
Does it return correctly
by resetting power?
YES
YES
Does the remote
control reset and start
automatically?
NO
NO
* Check whether the message of "It is in operation by standby" is still
displayed on the remote control, after 3minutes or more have elapsed.
Malfunction by noise
Check circumference
environment
Remote control anomaly
➞
Replace remote control
(Heat pump water heater is
normal)
Replace control P CB
Or replace remote control
. E rror detection method
If the communication between
remote control and heat pump
unit cannot be established
normally for minutes or more
during operation.
(It can be detected only by
remote control)
. Condition of error displayed
Same as above
. P resumable cause
• Anomaly of communication
circuit between remote control
and heat pump water heater
• N oise
N ote:
If the heat pump water heater cannot communicate with remote control normally for 0 seconds, the P CB of the heat
pump water heater automatically resets and starts
Error code
Remote control:
7-segment display:
LED
Green
Red
Heat pump
water heater
Keep
flashing
Stay off
Content
E
N o display
Communication error between
remote control and heat pump water heater
AMP Air Conditioning
www.ampair.co.uk | [email protected]
Содержание ESA30E-25
Страница 33: ... 15 HM T 246 Rear view Power transformer AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 69: ... 15 HM T 246 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 71: ... 15 HM T 246 0 WARNING CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 85: ... 15 HM T 246 4 3 System diagram 㪄㪈㪌㪄 AMP Air Conditioning www ampair co uk sales ampair co uk ...
Страница 91: ... 15 HM T 246 0 CAUTION AMP Air Conditioning www ampair co uk sales ampair co uk ...