11
- 3
11.1 System Configuration
11.1.1 Devices used for each base unit
11
MULTIPLE CPU SYSTEM CONFIGURATION
(2) When using the slim type main base unit (Q3 SB
)
* 1 Use a slim type power supply module.
The current consumption must be the rated output current or less.
Q series power supply modules and redundant power supply modules cannot be used.
* 2 The slim type main base unit does not have an extension cable connector.
Extension base units and a GOT are not connectable.
* 3 For the Q06CCPU-V-B, CompactFlash cards cannot be used.
* 4 For the Q06CCPU-V(-B), the Q7BAT cannot be used.
POINT
1. For combinations of configurable CPU modules, refer to the following.
2. A Motion CPU cannot be used when a slim type main base unit (Q3 SB) is
used.
Figure 11.2 When a slim type main base unit is used
CompactFlash card
(sold separately)
*3
Slim type main base unit
*1*2
Battery
*4
C Controller module
Slim type power supply module, I/O module,
intelligent function module