![Mitsubishi Electric Q06CCPU-V Скачать руководство пользователя страница 208](http://html.mh-extra.com/html/mitsubishi-electric/q06ccpu-v/q06ccpu-v_user-manual_1811831208.webp)
5
- 54
5.4 CC-Link IE Controller Network Module Access Function
5.4.4 Link device refresh setting
5
ACCESS VIA NETWORK MODULES
[Action 3: Modify the user program.]
Modify the task configuration, priority, processing details of the user program
so that the C Controller system specifications and user program processing
performance can be satisfied.
(c) Link device refresh cycle setting
Set a link device refresh cycle in "Link device refresh cycle" in the <<Parameter
settings>> tab.
Figure 5.52 Link device refresh cycle setting
Link device refresh cycle setting